Gore Medical has won FDA approval for an expanded indication of its VIABAHN VBX Balloon Expandable Endoprosthesis, making it the first bridging stent graft approved on-label for use in both fenestrated and branched endovascular aortic repair (FEVAR and BEVAR) in the United States. The company announced the approval on 14 October 2026, built on three-year outcomes from its EMBRACE registry presented days earlier at the European Society for Vascular Surgery meeting.
A bridging stent with no off-label workaround
FEVAR and BEVAR are minimally invasive techniques for complex aortic aneurysms that involve the renal or mesenteric arteries — cases a standard endograft cannot treat alone. The surgeon implants a custom-made endograft with fenestrations (openings) or side branches, then threads a separate bridging stent through each one to connect it to the target artery and keep blood flowing. For years, the bridging stent itself has been a balloon-expandable covered stent used off-label: cleared or approved for other indications, deployed in this role on the strength of published registries and individual surgeon judgment rather than a manufacturer-backed, FDA-reviewed indication.
What changed for vascular surgeons on October 14
First on-label bridge
VBX becomes the first device FDA has approved specifically as a bridging stent for both FEVAR and BEVAR, rather than one surgeons use for that purpose under an indication written for something else.
Customizable diameter and flare
The balloon-expandable design lets a surgeon size the stent's diameter and flare to a specific target vessel during the procedure, a fit other bridging options in use today also offer, but without FDA's review of that specific use.
Three years of registry evidence
The approval is backed by three-year outcomes from 268 patients across the EMBRACE registry's FEVAR and BEVAR cohorts, not a one-year snapshot.
What FDA actually expanded
The approval covers the use of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis as a bridging stent specifically in fenestrated and branched endovascular aortic repair — it does not change the device's existing iliac-artery indication, approved in 2017, and it is not a new product. Gore built its case on three-year results from the EMBRACE registry, a multicenter European study that began enrolling in 2023 to gather real-world data on VBX used this way, with target-vessel patency as its primary efficacy endpoint.
“The need for a standardized, evidence-based approach to bridging stent use has become increasingly important.” Gustavo Oderich, M.D., Professor and Chief, Division of Vascular Surgery and Endovascular Therapy, Baylor College of Medicine — Gore’s 14 October 2026 announcement
VBX's FEVAR/BEVAR case, in four figures
Figures from Gore’s 14 October 2026 announcement and three-year EMBRACE registry results presented at the European Society for Vascular Surgery meeting, 6–9 October 2026.
Where VBX stands against the stents used off-label
VBX is not the only balloon-expandable covered stent surgeons reach for in FEVAR and BEVAR. Getinge’s Advanta V12, sold in the U.S. as the iCAST covered stent, won its own FDA premarket approval for bridging stent use in aneurysmal disease in July 2025 — but that U.S. label is written around a general aneurysmal-disease indication, not the FEVAR- and BEVAR-specific language Gore secured. Bentley InnoMed’s BeGraft Peripheral remains off-label for this use in both the U.S. and Europe, with a German physician-initiated study recruiting toward an on-label FEVAR indication. Gore’s approval is the first to carry FEVAR- and BEVAR-specific label language in the U.S.
VBX against the other bridging options
| Product | Type | On-label for FEVAR/BEVAR | Manufacturer |
|---|---|---|---|
| GORE VIABAHN VBX | Balloon-expandable covered stent | Yes — FDA approved, Oct 2026 | Gore Medical |
| Advanta V12 / iCAST | Balloon-expandable covered stent | General aneurysmal-disease bridging label (US, Jul 2025); not FEVAR/BEVAR-specific | Getinge |
| BeGraft Peripheral | Balloon-expandable covered stent | No — used off-label (on-label study ongoing in Europe) | Bentley InnoMed |
From each company’s own labelling and published literature; not a clinical comparison.
What the aortic stent graft category is worth
$3.59B → $5.30B
Global aortic stent graft market, 2025 to 2030, as estimated by The Business Research Company (2026).
Sources: The Business Research Company, Aortic Stent Grafts Global Market Report 2026 · Technavio, Aortic Stent Grafts Market Analysis 2026-2030
Regulatory News outlook
We expect FEVAR/BEVAR bridging-stent volume to grow faster than the aortic stent graft category as a whole over the next few years, as an on-label option removes the documentation and liability friction that has slowed some centers’ adoption of fenestrated and branched repair for complex aneurysms; no publisher sizes that bridging-stent niche separately, so this is a directional view, not a figure of our own.
How we got here: Applying The Business Research Company’s published 7.9% compound annual growth rate to its $3.59 billion 2025 aortic stent graft baseline reaches roughly $5.30 billion by 2030; we have no independent figure for the FEVAR/BEVAR bridging-stent segment alone, so we read it as a faster-growing slice of that total rather than estimate a dollar figure for it.
From one iliac indication to two aortic ones
VBX's road to an on-label bridge
- 2017
First FDA approval
VBX wins FDA approval for de novo or restenotic lesions in the iliac arteries — its original indication.
- February 2023
EMBRACE registry launched
Gore begins a multicenter European registry evaluating VBX as a bridging stent in fenestrated and branched endografts, with target-vessel patency as the primary endpoint.
- July 2025
CE Mark for the bridging indication
The same expanded FEVAR/BEVAR bridging indication wins a CE Mark under the EU MDR, following EMBRACE's earlier results.
- 6–9 October 2026
Three-year EMBRACE results presented
Three-year outcomes across 268 FEVAR and BEVAR patients are presented at the European Society for Vascular Surgery meeting.
- 14 October 2026
FDA approval
FDA approves the expanded FEVAR/BEVAR bridging indication in the U.S., making VBX the first on-label device for both procedures.
- Ahead
Longer-term registry follow-up
Gore has not announced a date for results beyond three years, or for similar on-label reviews outside the U.S. and EU.
What the approval does not settle
An FEVAR/BEVAR-specific indication does not retire the Advanta V12/iCAST or BeGraft from these cases overnight: surgeons who have built case experience with another stent have limited reason to switch technique mid-practice, and Gore's announcement does not publish a specific PMA supplement number or detail how quickly hospitals are expected to update purchasing or protocols. What the approval changes is the paper trail — a documented, FDA-reviewed indication specific to FEVAR and BEVAR to point to, rather than a general aneurysmal-disease label or a published registry and individual judgment.
- What changed: VBX is now FDA-approved, not just used off-label, as a bridging stent in both FEVAR and BEVAR.
- Evidence base: three-year EMBRACE registry data across 268 patients (103 FEVAR, 165 BEVAR) and 662 target vessels.
- Not a new device: VBX's original iliac-artery indication dates to 2017; this is a label expansion.
- Not yet public: the specific PMA supplement number for this approval, which this article has not independently confirmed against FDA's own database.
Sources & further reading
- Gore Medical, “FDA Approves GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis for Expanded Use in FEVAR and BEVAR,” press release, 14 October 2026, as republished by Diagnostic and Interventional Cardiology (HMP Global). hmpgloballearningnetwork.com
- TCTMD, “Viabahn VBX Stent Graft Gains FDA-Approved Indications in Complex Aortic Disease,” October 2026. tctmd.com
- Endovascular Today, “Gore Viabahn VBX Stent Graft Gains FDA Approval for Use in FEVAR and BEVAR,” October 2026. evtoday.com
- Cardiovascular Business, “FDA approves aortic stent graft from Gore for FEVAR and BEVAR,” October 2026. cardiovascularbusiness.com
- MassDevice, “FDA approves Gore’s Viabahn VBX stent graft for iliac artery lesions,” 2017. massdevice.com
- Gore Medical, “Gore announces MDR expanded indication for the Viabahn VBX balloon-expandable endoprosthesis as a bridging stent,” July 2025. goremedical.com
- The Business Research Company, “Aortic Stent Grafts Global Market Report 2026.” thebusinessresearchcompany.com
- Vascular News, “Getinge’s iCast covered stent system approved as bridging stent in the USA,” 2025. vascularnews.com
- Gore Medical, VIABAHN VBX Balloon Expandable Endoprosthesis product page. goremedical.com
Regulatory News reports on public regulatory documents. It is not legal advice, and the primary sources above govern. If we have made an error, we will say so in public: see corrections.
Frequently asked questions
What did FDA approve for Gore's VBX stent graft?
An expanded indication allowing the GORE VIABAHN VBX Balloon Expandable Endoprosthesis to be used as a bridging stent in fenestrated and branched endovascular aortic repair (FEVAR and BEVAR), announced 14 October 2026. It is the first device with that specific on-label indication for both procedures in the United States.
Is VBX a new device?
No. FDA first approved VBX in 2017 for iliac artery lesions. The 14 October 2026 decision expands its labeling; it does not introduce a new product.
What are FEVAR and BEVAR?
Fenestrated and branched endovascular aneurysm repair — minimally invasive techniques for treating complex aortic aneurysms that involve the renal or mesenteric arteries, using a custom-made endograft with openings or side branches that a separate bridging stent connects to those target vessels.
Why does on-label status matter if surgeons already used VBX this way?
Balloon-expandable covered stents, VBX included, have been used as FEVAR/BEVAR bridges off-label for years, without a manufacturer-backed indication or FDA-reviewed evidence specific to that use. An on-label indication gives surgeons and hospitals an FDA-reviewed data package and labeling to point to, rather than relying on individual judgment and published registries alone.